Heat Pipe Air Pre-heater

日期: 2025-04-16

热管空气预热器

Equipment Name: Heat Pipe Air Preheater

Type: Vertical (horizontal flue gas flow)

Applications: Suitable for heating combustion air using exhaust gases from industrial furnaces such as thermal fluid heaters, boilers, and petrochemical heating furnaces.

Flue Gas Temperature: Below 350°C

Exhaust Gas Temperature: Approximately 130°C–200°C (adjustable as needed)

Inlet Air Temperature: 20°C–30°C

Outlet Air Temperature: 100°C–250°C

Features:

  1. Utilizes heat pipe heat transfer principles, ensuring resistance to dew-point corrosion.

  2. Compact design with a small footprint.

  3. Complete separation of flue gas and air, ensuring zero leakage.

  4. Free expansion of heat pipes, eliminating thermal stress.

  5. No moving parts, resulting in low operation and maintenance costs.